arm64: dts: disable unused AST USB3 AHP controller - #289
Open
ankitaprasad2206 wants to merge 1 commit into
Open
Conversation
rajaganeshr
reviewed
Jul 27, 2026
rajaganeshr
left a comment
Collaborator
There was a problem hiding this comment.
can you add all 2P platforms? Hornbill, Seagull etc.
the secondary ASPEED USB3 AHP/vHUB path is not used but remains enabled in the device tree. This results in an extra ASPEED USB controller being enumerated by the OS and causes the Windows Server HLK USB Exposed Port Test to fail. Tested: Tested on SP7 2P system. - It successfully disables Port A’s PCIe-XHCI-PHY and does not expose it to Windows. Signed-off-by: ankprasa <ankprasa@amd.com>
ankitaprasad2206
force-pushed
the
Fixing-HLK-Test-USB-Issue
branch
from
July 27, 2026 15:57
f25182f to
b4b11dd
Compare
Collaborator
Author
done |
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
the secondary ASPEED USB3 AHP/vHUB path is not used but remains enabled in the device tree. This results in an extra ASPEED USB controller being enumerated by the OS and causes the Windows Server HLK USB Exposed Port Test to fail.
Tested: Tested on SP7 2P system.