Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Adds a Windows WPF launcher for offices supervised by scheduled tasks, with Start, Stop, Restart, health/task status and bounded live log tabs. Stop targets only the direct server/SSH children of the configured supervisors, preserving worker process trees. Closing the GUI leaves services running.
Documents configuration and render-only preview mode. UTF-8 BOM and encoding-aware log reads support Windows PowerShell 5.1.
Validation: typecheck and build passed; WPF screenshot visually inspected; isolated process-control check passed. Full npm test stalled. Bounded rerun: 550 passed, 36 failed, 4 cancelled, including Windows process/cleanup issues and timeouts. The existing suite is not green on this machine. Live workers were not interrupted for control tests.