Skip to content
Closed
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
Original file line number Diff line number Diff line change
@@ -1,75 +1,18 @@
use super::*;

/// SAFETY backstop on continuous-batching lanes for a single base model on one
/// node — NOT the binding constraint. The binding constraint is now the
/// compute-buffer-aware fit math ([`ModelFootprint::compute_buffer_per_lane`] +
/// the per-lane floor and window reserve in [`plan_serving`]): the lane count
/// follows persona DEMAND, capped by how many lanes' (KV + concurrent compute
/// buffer) actually fit THIS host's budget. That is the #139/#56 "lane-scaled
/// compute-buffer HEADROOM term so the ceiling derives from model size instead of
/// a constant" — it makes N-lane serving OOM-safe by construction.
/// ONE LANE. One mind decodes at a time on a node's engine; the next mind is staged as
/// data and the previous one retires to RAM, so a switch binds her blocks instead of
/// re-prefilling them (Joel, 2026-11-18: "We do one lane";
/// [[one-mind-decodes-at-a-time-parallel-decode-collapses-throughput]]). Concurrent decode
/// splits one engine's rate across minds: on the M5, 4 minds at once ran ~2 tok/s each,
/// while one mind runs ~80 (measured 2026-11-17, #6114). That is less total and ~30x
/// slower per answer, and each extra lane also splits the KV budget into smaller windows.
/// A node with several minds serves them by switching, not by more lanes.
///
/// History: this was `2`, a flat clamp added 2026-07-14 after four concurrent
/// prefill compute buffers (a transient ~batch-sized per-slot Metal allocation NOT
/// in the KV arithmetic) blew the pool during a wake-briefing burst
/// (`kIOGPUCommandBufferCallbackErrorOutOfMemory`). But `2` was calibrated for a
/// ~16 GB budget and mis-applied to a 64 GB (≈55 GB Metal working-set) host, where
/// it left ~29 GB idle and forced 4 personas onto 2 slots — the cross-persona KV
/// clobber that is #139's whole latency story (each turn re-prefills ~10k cold
/// because the slot was last written by a different persona's prompt+LoRA). With the
/// compute buffer now RESERVED in the fit math, giving each persona its own warm
/// slot is memory-safe. This ceiling stays only to bound pathological demand (a
/// runaway roster) and llama.cpp `--parallel` practicality; real fit is the fit math.
///
/// 2026-07-16 RAISED 2 → 4 — the window-scaled compute term the earlier revert
/// demanded now EXISTS. History: raised 2→6, reverted 6→2 same day (OOM) because the
/// `compute_buffer_per_lane` reserve was a window-INDEPENDENT constant, so a 4-lane plan
/// at a large served window under-provisioned the transient prefill buffer (which scales
/// `O(ubatch × n_ctx)`) and 4 concurrent large-window prefills blew the Metal pool
/// (`kIOGPU…OutOfMemory`). The prerequisite named there — "a WINDOW-SCALED compute term
/// (reserve ∝ n_ctx)" — landed in [`plan_serving`] (commit 0925aa1ac): the served window
/// now SOLVES THE FIXPOINT, shrinking so `lanes × (KV(C) + compute(C))` fits every lane,
/// AND reserves co-consumer headroom. So more lanes no longer overcommit — the window
/// auto-shrinks to pay for them (`served_window_footprint_fits_effective_budget…` pins
/// the invariant). 4 = the resident-persona count: each mind gets its OWN warm slot, so a
/// turn reuses ITS prefilled KV instead of re-prefilling ~10k cold after a slot-mate
/// clobbered it (#139's whole latency story). Still a SANITY backstop, not the binding
/// constraint — the real cap is the fit math (`kv_lanes`) ∩ DEMAND ∩ perf cores; this
/// only bounds a pathological roster and llama.cpp `--parallel` practicality. Kept modest
/// (4, not the 6 that OOM'd) pending a LARGE-prompt 4-lane live-GPU burst — the doc's
/// acceptance gate. [[verify-real-device-numbers-not-a-clamp-premise]] [[capacity-fabric-live-never-block-sim-as-gym]]
pub const MAX_LANES: u32 = 8;
/// This replaces a ceiling that moved 2 -> 4 -> 2 -> 8 between 2026-07 and 2026-08, each
/// time chasing a per-slot window or warm-slot trade-off that more lanes cannot win.
pub const MAX_LANES: u32 = 1;

// ⚠️ 2026-07-17 REVERTED 4 → 2. Raising to 4 (warm slot per persona) was OOM-SAFE
// (the window-scaled fit shrank -c to fit) but STARVED CONTEXT: splitting the budget 4
// ways dropped the per-slot window to ~6k, and a live persona's assembled prompt is ~9k
// (identity + tools + workspace-map + recall + memory), so every persona got
// budget-truncated to fit — the "120k clamped to 3k → all models suck" regression, plus
// a 145s decode loop on the starved/confused context. Warmth is worthless if the mind
// can't see. The 4-lane premise was wrong: personas are NOT all concurrently active, so
// lanes should follow real concurrent DEMAND (usually 1–2), not the resident count —
// 2 lanes at ~19.8k each beats 4 warm lanes at 6k. Cross-turn clobber (the reason for the
// raise) is the lesser evil vs a starved window; solve it with idle-warmth/duty-cycling,
// NOT by cutting everyone's context. [[no-hardcoded-context-numbers-derive-from-the-live-window]]
//
// ✅ 2026-08-09 RAISED 2 → 8 (#266). The 2026-07-17 revert diagnosed the failure correctly
// (a starved per-slot window) but fixed it in the WRONG place: it clamped the lane CEILING,
// when the real defect was that the lane-COUNT gate below sheds against `MIN_SERVE_CTX`
// (2048, the "runnable at all" floor) — far below the ~9k a live turn needs — so a raised
// ceiling let 4 slots @ 6k through. That is now fixed at the true seam: the shed in
// `plan_serving` requires each slot to clear `BOOTSTRAP_WORKING_SET` (16384 ≈ a full
// assembled turn + generation headroom), the SAME "one full turn" figure the demand cap
// uses. With that usable-window floor as the binding constraint, a slot per resident persona
// is safe BY CONSTRUCTION — the plan only grows lanes toward the resident population while
// each still gets a full turn, and sheds (surfacing `grid_overflow_lanes` + a probe) the
// moment the floor would be breached, never below it. The 2026-07-17 "solve clobber with
// duty-cycling, not lanes" stance was itself the bug this leaves on the table: cross-turn
// KV clobber IS #266's whole latency story (measured: 96.3% of persona compute is prefill;
// two of four citizens at 0.0% cache reuse across 10 turns — the LRU eviction of a warm
// slot the resident count outnumbered). Giving each resident mind its own slot is what
// keeps its prefilled prefix warm. This constant is once again a pure SANITY backstop
// (pathological roster + llama.cpp `--parallel` practicality); the binding constraint is
// the window floor, exactly as the earlier doc always claimed it should be.
/// Cold-start DEMAND ceiling for the served window — the "B-now" half of the
/// demand-derived cap (M5 + BigMama, 2026-07-26). Sizing a lane's window to fill
/// the memory budget instead of to real demand is the cross-node serving-quality
Expand Down
Loading