What was wrong: Stop-PkProcessTree redirected taskkill's stdout and stderr but never read them. taskkill prints a line per process it kills (three for a cmd /c tool job), so once about 20 jobs were running the pipe filled and taskkill blocked. The 10 s wait then gave up, and the fallback Kill() only reached the top-level processes, leaving their children running. Every force-stop and teardown kills all running jobs in one call, so any batch running that many jobs at once could hit it.

What changed: both pipes are read (ReadToEndAsync()) as soon as taskkill starts, and the reads get a short bounded wait once it exits.

Tested: new harness assertion: 40 cmd /c ping trees through Stop-PkProcessTree, all gone in under 5 s. Before the fix it took 10 s on both runtimes and left 19 pings running on 5.1. After it, 0.2 s with none left on both. Full harness passes on Windows PowerShell 5.1 and PowerShell 7.