3 changes: 3 additions & 0 deletions CHANGELOG.md
Original file line number Diff line number Diff line change
Expand Up @@ -2,6 +2,9 @@

## [4.19.1rc] - 2026-11-23 not released in PyPi

- [FIXED] the rectangular AC model fixes an angle in every synchronous area, not only at the reference node. An area joined to
the rest only through HVDC, or a bus no AC branch reaches, was free to rotate, and the NLP was singular. On a Nordic case with
45 such areas, Ipopt goes from 505 and 769 iterations at the acceptable level to 142 and 191, optimal, at the same cost.
- [FIXED] save the per load level cost results for every stage to print them in cost summary.
- [FIXED] protect against ESS without charge capacity and without inflows.
- [ADDED] `--output-format csv|duckdb|both` in `openTEPES_Main`, and a command line for a sweep:
Expand Down
47 changes: 47 additions & 0 deletions openTEPES/openTEPES_ModelFormulationElectricity.py
Original file line number Diff line number Diff line change
Expand Up @@ -1360,6 +1360,34 @@ def _tap(mTEPES, la):
return mTEPES.pLineTapFactor[la]


def _SynchronousAreaAnchors(mTEPES, p):
"""The parts of the AC network of period p that do not hold the reference node, as {anchor bus: buses of the part}.

A part is joined to the rest only through HVDC, or is a bus no AC branch reaches. Its anchor is its bus with the most AC
neighbours, the first by name among equals, so the choice does not depend on the order of the input."""
pGraph = nx.Graph()
pGraph.add_nodes_from(mTEPES.nd)
pGraph.add_edges_from((ni, nf) for ni, nf, cc in mTEPES.laa if (p, ni, nf, cc) in mTEPES.pla)
pRef = mTEPES.rf.first()
return {max(sorted(pArea), key=pGraph.degree): sorted(pArea) for pArea in nx.connected_components(pGraph) if pRef not in pArea}


def _AnchorAreaAngles(OptModel, mTEPES, p, sc, pAnchors):
"""Rotate the start voltages of each part of pAnchors so that its anchor bus has angle zero, and fix that angle again.

The cone projection and the power flow start set each part's angles from a reference of their own choosing, so the start
is rotated afterwards to agree with the angle the model fixes. A rotation of a whole part changes no flow."""
for n in mTEPES.n:
for pAnchor, pBuses in pAnchors.items():
pTheta = math.atan2(OptModel.vVim[p,sc,n,pAnchor].value or 0.0, OptModel.vVre[p,sc,n,pAnchor].value or 1.0)
c, s = math.cos(pTheta), math.sin(pTheta)
for nd in pBuses:
pRe, pIm = OptModel.vVre[p,sc,n,nd].value or 0.0, OptModel.vVim[p,sc,n,nd].value or 0.0
OptModel.vVre[p,sc,n,nd].set_value( pRe * c + pIm * s)
OptModel.vVim[p,sc,n,nd].set_value(- pRe * s + pIm * c)
OptModel.vVim[p,sc,n,pAnchor].fix(0.0)


def SettingUpVariablesBIM(OptModel, mTEPES, pMode=None):
"""Declare the bus-injection voltage variables. Returns the number of variables fixed.

Expand Down Expand Up @@ -1405,6 +1433,19 @@ def SettingUpVariablesBIM(OptModel, mTEPES, pMode=None):
OptModel.vVre[p,sc,n,ref].fix(mTEPES.pVNom())
OptModel.vVim[p,sc,n,ref].fix(0.0)
nFixed += 2
# Every other synchronous area (a part of the network joined to the reference only through HVDC, or a bus with no AC branch)
# needs an angle reference of its own: without one, rotating all its voltages leaves every flow unchanged and the NLP is singular.
# Only the angle is fixed there; the magnitude stays free within the bus's band, and with the imaginary part at zero the real
# part is the magnitude, so it is bounded below by the band floor.
for p in mTEPES.p:
pAnchors = list(_SynchronousAreaAnchors(mTEPES, p))
for sc, n in ((sc, n) for pp, sc, n in mTEPES.psn if pp == p):
for nd in pAnchors:
OptModel.vVim[p,sc,n,nd].fix(0.0)
OptModel.vVre[p,sc,n,nd].setlb(mTEPES.pVMinBus[nd])
nFixed += 1
if pAnchors:
print(f'Angle reference added in {len(pAnchors)} synchronous areas without the reference node, period {p}')

print('Setting up BIM variables ... ', round(time.time() - StartTime), 's')
return nFixed
Expand Down Expand Up @@ -1676,10 +1717,16 @@ def ACConeWarmStart(OptModel, mTEPES, DirName, CaseName, SolverName, pIndLogCons
if not hasattr(mTEPES, 'pACConeBound'):
mTEPES.pACConeBound = {}
mTEPES.pACConeBound[(p, sc, st)] = pBound
# the angle references of the parts without the reference node are freed while the start is computed, see _AnchorAreaAngles
pAnchors = _SynchronousAreaAnchors(mTEPES, p)
for n in mTEPES.n:
for pAnchor in pAnchors:
OptModel.vVim[p,sc,n,pAnchor].unfix()
nSet = _ProjectConeToVoltages(OptModel, mTEPES, p, sc)
print(f'AC cone lower bound ... {pBound:.6f} MEUR, {nSet} bus voltages set from it')
if mTEPES.pIndACConeStart() == 2:
_PowerFlowFromProjection(OptModel, mTEPES, p, sc, st)
_AnchorAreaAngles(OptModel, mTEPES, p, sc, pAnchors)
else:
print('### WARNING: the cone warm start found no cone solution; the rectangular model starts from the flat profile.')

Expand Down
108 changes: 108 additions & 0 deletions tests/test_ac_hvdc_and_setpoints.py
Original file line number Diff line number Diff line change
Expand Up @@ -114,6 +114,114 @@ def test_angles_available_tolerates_a_node_with_no_ac_branch(tmp_path):
assert angles_available(mTEPES, mTEPES, *first)


def test_rectangular_model_fixes_an_angle_in_every_synchronous_area(tmp_path):
"""A node no AC branch reaches gets an angle reference of its own in rectangular coordinates.

Only the reference node had one. Rotating the voltage of the pole changes no flow, so the pole's angle was a free direction
of the NLP and Ipopt met a singular problem. The angle is fixed at zero and the magnitude stays free within the band.
"""
d, n = _with_dc_only_node(tmp_path, "9n_AC_pole_rect")
opt = pd.read_csv(os.path.join(d, n, f"oT_Data_Option_{n}.csv"))
opt["IndACPowerFlow"] = 3
_write(d, n, "Option", opt)
mTEPES, _, _ = _build(d, n, with_vars=True)

ref = mTEPES.rf.first()
for p, sc, nn in mTEPES.psn:
assert mTEPES.vVim[p, sc, nn, "DCpole"].fixed and mTEPES.vVim[p, sc, nn, "DCpole"].value == 0.0
assert not mTEPES.vVre[p, sc, nn, "DCpole"].fixed
assert mTEPES.vVre[p, sc, nn, "DCpole"].lb == pytest.approx(mTEPES.pVMinBus["DCpole"])
# the rest of 9n_AC is one synchronous area with the reference node: no other angle is fixed
assert {nd for nd in mTEPES.nd if mTEPES.vVim[p, sc, nn, nd].fixed} == {ref, "DCpole"}


def _with_dc_only_area(tmp_path, name):
"""9n_AC with buses 7, 8 and 9 joined to the rest only through DC: the three AC branches that cross over are made DC.

That is the shape of an AC area behind HVDC, such as Western Denmark in a Nordic case. Inside the area 7-8 and 8-9 stay AC,
so bus 8 has the most AC branches there and is the anchor."""
d, n = _clone(tmp_path, "9n_AC", name)
net = pd.read_csv(os.path.join(d, n, f"oT_Data_Network_{n}.csv"))
cut = {("Node_6", "Node_7"), ("Node_6", "Node_8"), ("Node_4", "Node_9")}
net.loc[[(a, b) in cut for a, b in zip(net.InitialNode, net.FinalNode)], "LineType"] = "DC"
_write(d, n, "Network", net)
opt = pd.read_csv(os.path.join(d, n, f"oT_Data_Option_{n}.csv"))
opt["IndACPowerFlow"] = 3
_write(d, n, "Option", opt)
return d, n


def test_an_area_behind_hvdc_is_anchored_at_its_best_connected_bus(tmp_path):
"""One angle per area: bus 8 is fixed, buses 7 and 9 stay free, and the area is found again with the same anchor."""
from openTEPES.openTEPES_ModelFormulationElectricity import _SynchronousAreaAnchors

d, n = _with_dc_only_area(tmp_path, "9n_AC_area_build")
mTEPES, _, _ = _build(d, n, with_vars=True)
assert mTEPES.rf.first() == "Node_4"
for p in mTEPES.p:
assert _SynchronousAreaAnchors(mTEPES, p) == {"Node_8": ["Node_7", "Node_8", "Node_9"]}
for p, sc, nn in mTEPES.psn:
assert {nd for nd in mTEPES.nd if mTEPES.vVim[p, sc, nn, nd].fixed} == {"Node_4", "Node_8"}


def test_rotating_an_area_to_its_anchor_changes_no_flow(tmp_path):
"""The cone start rotates each area so that its anchor has angle zero. The magnitudes and every V_i conj(V_j), which
is all a flow depends on, stay as they were, and the anchor angle is fixed again."""
import cmath
from openTEPES.openTEPES_ModelFormulationElectricity import _AnchorAreaAngles, _SynchronousAreaAnchors

d, n = _with_dc_only_area(tmp_path, "9n_AC_area_rotate")
mTEPES, _, _ = _build(d, n, with_vars=True)
p, sc, _ = next(iter(mTEPES.psn))
pAnchors = _SynchronousAreaAnchors(mTEPES, p)
pStart = {"Node_7": cmath.rect(1.02, 0.31), "Node_8": cmath.rect(0.99, 0.42), "Node_9": cmath.rect(1.01, 0.37)}
for nn in mTEPES.n:
mTEPES.vVim[p, sc, nn, "Node_8"].unfix()
for nd, v in pStart.items():
mTEPES.vVre[p, sc, nn, nd].set_value(v.real)
mTEPES.vVim[p, sc, nn, nd].set_value(v.imag)

_AnchorAreaAngles(mTEPES, mTEPES, p, sc, pAnchors)

for nn in mTEPES.n:
V = {nd: complex(mTEPES.vVre[p, sc, nn, nd].value, mTEPES.vVim[p, sc, nn, nd].value) for nd in pStart}
assert mTEPES.vVim[p, sc, nn, "Node_8"].fixed and mTEPES.vVim[p, sc, nn, "Node_8"].value == 0.0
assert V["Node_8"].real == pytest.approx(0.99)
for i in pStart:
assert abs(V[i]) == pytest.approx(abs(pStart[i]))
for j in pStart:
assert V[i] * V[j].conjugate() == pytest.approx(pStart[i] * pStart[j].conjugate())


@pytest.mark.solve
def test_an_area_behind_hvdc_reaches_the_same_optimum_from_every_start(tmp_path):
"""The flat start, the cone start and the power flow start all reach one optimum on a case with an AC area behind HVDC,
and the anchor ends the solve with angle zero. The two cone starts free the anchor angle and fix it again."""
if not SolverFactory("ipopt").available(exception_flag=False):
pytest.skip("ipopt is not available")
from openTEPES.openTEPES import openTEPES_run

pCost = {}
for pStart in (0, 1, 2):
d, n = _with_dc_only_area(tmp_path / f"s{pStart}", f"9n_AC_area_start{pStart}")
_first_hours(d, n, hours=2)
opt = pd.read_csv(os.path.join(d, n, f"oT_Data_Option_{n}.csv"))
opt["IndACConeStart"] = pStart
_write(d, n, "Option", opt)
try:
mTEPES = openTEPES_run(d, n, "ipopt", pIndOutputResults=0, pIndLogConsole=0)
except Exception as e:
if "size-limited" in str(e) or "too large" in str(e).lower():
pytest.skip("the solver licence cannot take a model this size")
raise
pCost[pStart] = mTEPES.vTotalSCost()
for p, sc, nn in mTEPES.psn:
assert mTEPES.vVim[p, sc, nn, "Node_8"].fixed and mTEPES.vVim[p, sc, nn, "Node_8"].value == 0.0
assert mTEPES.vVre[p, sc, nn, "Node_8"].value >= mTEPES.pVMinBus["Node_8"] - 1e-6
for pStart in (1, 2):
assert pCost[pStart] == pytest.approx(pCost[0], rel=1e-4), f"start {pStart} gives {pCost[pStart]}, the flat start {pCost[0]}"


def test_angles_available_still_refuses_an_unset_ac_node(tmp_path):
"""A node that an AC branch does touch must still carry an angle.

Expand Down