Repository navigation
Ifc: add options for Revit parameter units and display names - #330
Merged
Merged
Conversation
With display or builtin names selected, properties that would share a name in a set get a parameter ID suffix. With IFC units, every measure has a declared unit, the length exponents of several specs are corrected and a spec is no longer guessed from the parameter name. Both parameter options turn on the Revit property sets with a configuration file too.
3 of 4 tasks
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Closes #323
Summary
--ifc-revit-parameter-units <ifc|internal>and--ifc-revit-parameter-names <display|builtin>CLI flags,IfcPropertySetConfiguration/IfcExportConfigurationsettings (revitParameterUnits,revitParameterNames),IfcExporterproperties, JSON round-trip, validation, and--ifc-capabilitiesentries.0.3048^L) and IFC measure types whenifcunits are selected.BuiltInParametername inIFCPROPERTYSINGLEVALUE.Descriptionand keeping distinct descriptions separate in the property value cache.--ifc-revit-parameters/--ifc-revit-parameter-groupsdefaults when the new options are not specified.docs/ifc-export.mdandREADME.mdand add synthetic unit/config/CLI tests inIfcExporterRevitParameterFormattingTests.Verification
dotnet test tests/RvtIO.Tests/RvtIO.Tests.csproj -c Release: 12205 passed, 0 failed, 453 skipped (net10.0); 12201 passed, 0 failed, 453 skipped (net8.0).dotnet build src/RvtIO.Scene/RvtIO.Scene.csproj -c Release -p:BuildNativeCoreOnly=true: 0 errors.