Route pylink-square-mcp through J-Link Remote Server backend #52
The pylink-square MCP server crashes periodically. Root cause hypothesis: every tool call creates a fresh pylink.JLink(), opens USB, connects, and discards -> repeated DLL load/unload + USB churn in a long-lived process.
Goal:
Make J-Link Remote Server on localhost (default port 19020) the default connection backend for all scripts in tools/pylink-square-mcp.
mcp_server.py should launch JLinkRemoteServer (-Port, optional -USB <serial/nickname>) on startup if it is not already listening, then persist across MCP restarts.
Per SEGGER KB (https://kb.segger.com/J-Link_Remote_Server), JLinkRemoteServerCLExe takes -Port and -USB (S/N or nickname) options; device/speed stay client-side in pylink connect(). Client connects via jlink.open(ip_addr='127.0.0.1:').
Activity
emrainey commentedon Aug 11, 2026
Implemented on branch
issue-52→ PR #53.mcp_server.pynow launchesJLinkRemoteServer -Port <port> [-USB <serial>]on startup if not listening and leaves it running across MCP restarts.--device/--speed/--remote-port/--usb-serialCLI opts withJLINK_MCP_*env fallbacks.tools(pylink-square-mcp): route through persistent J-Link Remote Serv…
Route pylink-square-mcp through a persistent J-Link Remote Server (#53)