Checks how well demand profiles match measured reality during peak weeks and cold spells. For each historical year, every method rebuilds that year's profile from only its weather, calendar and annual total, and is compared with the measured data (leave-one-year-out).
- Python 3.12 (on Windows via the
pylauncher) and Git - The input data files — not in the repo; get them from the shared folder
py -3.12 -m venv .venv
.\.venv\Scripts\Activate.ps1
python -m pip install -r requirements.lock
python -m pip install -e . --no-depsrequirements.lock pins the exact package versions, so everyone gets the same
environment. Optional check: python -m pytest -q (all tests should pass).
Put the files in data/raw/. File names and settings are in config.yaml.
| File | Format | Notes |
|---|---|---|
ENAGAD.csv |
JRC ENaGaD daily gas demand, as downloaded | Measured demand, NL, GWh per gas day. Carrier heat uses column DIS (distribution grid, residential + commercial); carrier gas_total uses TOT (all gas). Gas day D runs 06:00 to 06:00 the next day (local time). |
Profielen-*aardgas-*.zip |
Official Dutch standard gas profiles, zips as downloaded | Reference method NEDU: category weights under nedu.weights (default G1A 0.75, G2A 0.25; add GXX once its volume is known). |
Warmteprofiel *.xlsx |
WPG export: time, Ruimteverwarming_W, Tapwater_W (hourly, local time) |
Not used at the moment (see the backup section in docs/results.md). |
uurgeg_<station>_*.txt / .zip |
KNMI hourly export (uurgegevens, the .txt or .zip as downloaded) with T, FH, FF, Q |
Averaged to gas days automatically. List the files under weather.path. weather.stations: nedu uses the 6 official TAC stations and weights (260, 290, 380, 235, 280, 310), renormalised over the stations present. TAC is computed per station, then weighted. Cover up to 1 January after the last year. |
electricity.csv (optional) |
timestamp_utc,value |
Hourly, UTC, e.g. 2018-02-28T23:00:00Z,12345. Test bench only. |
Years with less than 90% data are skipped and listed in the output.
.\.venv\Scripts\Activate.ps1 # in each new terminal
python -m src.run_loyo --config config.yaml --carrier heat gas_totalUse --carrier electricity for the test bench.
Written to results/<carrier>/:
| File | Content |
|---|---|
tables/summary.csv |
One row per method: peak-week, top-1%, annual-mean, nRMSE and cold-spell errors in %; mean, worst and coldest year. Ready for the Result slide. |
figures/fig1_peak_week.png |
Measured (black) vs. each method in the coldest year's peak week |
figures/fig2_metric_bars.png |
Peak-week and top-1% errors per method |
figures/fig3_annual_scatter.png |
Measured vs. rebuilt, coldest year |
figures/fig4_loyo.png |
Peak-week error per year |
figures/fig5_external_<year>.png |
Per WPG year: measured vs. A* and the models, full year and peak week |
tables/summary_external_years.csv |
Like summary.csv, but only the WPG years, so A* is compared like-for-like |
metrics.json |
All numbers, data coverage and included/excluded years |
Data sources, methods, metrics, limitations and the synthetic demo: docs/details.md. Results so far: docs/results.md. Standard gas profiles vs learning, full method and numbers: docs/technical_reference.md; presentation (open in a browser): docs/presentation/standard_profiles_vs_learning.html, technical appendix: docs/presentation/standard_profiles_vs_learning_appendix.html.