A golang command line based modbus server simulator

Resources

Stars

0 stars

Watchers

0 watching

Forks

Repository files navigation

modbus-simulator

Go Go Reference License CI Code Coverage Release

Deterministic, stateful Modbus TCP device simulator for integration and end-to-end testing. Load a declarative JSON fixture (raw registers or go-modbus codec fields with typed values), serve one or more Modbus devices from a single listener (plain TCP or TLS), optionally record a JSONL trace of every request, and assert traces in CI.

Repository: github.com/otfabric/modbus-simulator

See REQUIREMENTS.md for the full specification.

Table of contents

Install

Download a pre-built binary for Linux, macOS or Windows from GitHub Releases, or install with Go (1.25+):

go install github.com/otfabric/modbus-simulator@latest

Or build from a checkout:

make build          # lint + test, then bin/modbus-simulator
make install        # copies to /usr/local/bin (uses sudo)

make build runs the full make check first and needs staticcheck and golangci-lint v2 on PATH. For a plain build without them: go build -o bin/modbus-simulator .

Quick start

Validate a fixture and start the simulator:

FIXTURE=examples/all-function-codes.json

modbus-simulator validate "$FIXTURE"
modbus-simulator run --fixture "$FIXTURE" --listen :1502

While the simulator runs, point your Modbus client or gateway at tcp://127.0.0.1:1502 (unit ID 1).

For trace recording and CI assertions, add --trace trace.jsonl, generate traffic, stop the server (Ctrl+C), then run assert-trace with an expectation file — see assert-trace and Artifacts.

Per–function-code and codec fixtures are in Examples. Command details and flags are in Commands below.

Commands

modbus-simulator [--debug]
├── validate <fixture.json>
├── run
├── assert-trace <trace.jsonl>
├── codecs list
├── version
└── completion [bash|zsh|fish|powershell]

Global flags

Flag Default Description
--debug false Print debug information (applies to all commands)

validate

Validate a fixture against the embedded JSON Schema and semantic rules.

Flags

Flag Environment variable Default Description
--format MODBUS_SIMULATOR_FORMAT text Output format: text or json

Examples

# Exit 0 on success, 3 on validation failure
modbus-simulator validate device.json

# Machine-readable summary
modbus-simulator validate device.json --format json

run

Start the stateful Modbus TCP simulator from a fixture. Runs until interrupted (SIGINT/SIGTERM).

Flags

Flag Environment variable Default Description
--fixture MODBUS_SIMULATOR_FIXTURE (required) Path to fixture JSON
--listen MODBUS_SIMULATOR_LISTEN :5020 TCP listen address (host:port)
--trace MODBUS_SIMULATOR_TRACE (none) JSONL trace output path
--trace-decoded MODBUS_SIMULATOR_TRACE_DECODED false Include typed codec decode overlay in trace records
--trace-raw MODBUS_SIMULATOR_TRACE_RAW false Include the request and response PDU bytes (hex) in trace records
--max-clients MODBUS_SIMULATOR_MAX_CLIENTS 0 (unlimited) Max concurrent clients; a client over the limit is disconnected
--control MODBUS_SIMULATOR_CONTROL (disabled) HTTP control API address (host:port) — see State, reset and reload
--tls-cert MODBUS_SIMULATOR_TLS_CERT (none) Server certificate (PEM) — see TLS
--tls-key MODBUS_SIMULATOR_TLS_KEY (none) Server private key (PEM)
--tls-client-ca MODBUS_SIMULATOR_TLS_CLIENT_CA (none) CA certificates (PEM) that client certificates must chain to

Examples

# Serve on the default port (:5020)
modbus-simulator run --fixture device.json

# Custom listen address and trace output
modbus-simulator run --fixture device.json --listen :1502 --trace trace.jsonl

# Trace with typed codec decode overlay and the PDU bytes
modbus-simulator run --fixture examples/codec-floats.json --trace trace.jsonl --trace-decoded --trace-raw

# Control API for reset and reload
modbus-simulator run --fixture device.json --control 127.0.0.1:5021

# TLS with client certificates
modbus-simulator run --fixture device.json --tls-cert server.pem --tls-key server.key --tls-client-ca ca.pem

# Environment variables instead of flags
MODBUS_SIMULATOR_FIXTURE=device.json MODBUS_SIMULATOR_LISTEN=:5020 modbus-simulator run

codecs list

List go-modbus codec stable IDs and metadata. Use these IDs in fixture codec fields.

Flags

Flag Environment variable Default Description
--family (none) (none) Filter by family: integer, float, text, bcd, bytes, network, hardware_address, decimal_limb, time, …
--format MODBUS_SIMULATOR_FORMAT text Output format: text or json

Examples

modbus-simulator codecs list
modbus-simulator codecs list --family float --format json

assert-trace

Assert a JSONL trace against an expectation file (modbus-simulator.expect.v1).

Flags

Flag Environment variable Default Description
--expect MODBUS_SIMULATOR_EXPECT (required) Path to expectation JSON
--format MODBUS_SIMULATOR_FORMAT text Output format: text or json

Examples

# Exit 8 if any assertion fails
modbus-simulator assert-trace trace.jsonl --expect expected.json

# Machine-readable report
modbus-simulator assert-trace trace.jsonl --expect expected.json --format json

version

Print build metadata (version, tag, commit, build date).

Flags

None.

Examples

modbus-simulator version

completion

Generate shell completion scripts for bash, zsh, fish, or powershell.

Flags

None (shell name is a required positional argument).

Examples

# Bash
source <(modbus-simulator completion bash)

# Zsh
source <(modbus-simulator completion zsh)

# Fish
modbus-simulator completion fish | source

# PowerShell
modbus-simulator completion powershell | Out-String | Invoke-Expression

Exit codes

Code Meaning
0 Success
2 Usage / flag error
3 Validation error (invalid fixture, trace, or expectation)
4 Transport / server error
8 Assertion failure
10 Internal error

Artifacts

Three JSON artifacts drive the workflow:

Artifact schemaVersion Schema file Published $id
Fixture modbus-simulator.fixture.v1 schemas/fixture-v1.json https://otfabric.dev/schemas/modbus-simulator/fixture-v1.json
Trace (JSONL) modbus-simulator.trace.v1 schemas/trace-v1.json https://otfabric.dev/schemas/modbus-simulator/trace-v1.json
Expectation modbus-simulator.expect.v1 schemas/expect-v1.json https://otfabric.dev/schemas/modbus-simulator/expect-v1.json
schemas/
├── fixture-v1.json    # device state, identity, behavior (raw + codec register points)
├── trace-v1.json      # one JSON object per served request (JSONL)
└── expect-v1.json     # trace assertions (contains, count, ordered, exact, …)
  • Fixture — declarative initial Modbus world; raw uint16/bool points or codec-backed multi-register fields with typed values. Semantic validation uses the go-modbus codec registry (see validate and codecs list).
  • Trace — append-only execution log; optional output from run --trace.
  • Expectation — subset matchers evaluated by assert-trace.

Schemas are embedded in the binary so validate and assert-trace work offline. Set "$schema" in your JSON to the published $id or a relative path (e.g. "schemas/fixture-v1.json") for editor validation; the CLI selects the schema from schemaVersion, not from $schema.

Codec register fields

Register points in a fixture can use raw unsigned integers (0–65535, one register each) or a go-modbus codec with a typed JSON value. The simulator encodes codec values to wire registers at load time; FC handling stays register-native on the wire.

Raw point:

{ "address": 100, "value": 2301, "writable": false, "name": "raw_counter" }

Codec point:

{
  "address": 10,
  "codec": "float32/layout:4321",
  "value": 230.5,
  "writable": true,
  "name": "voltage"
}
Field Meaning
codec Stable ID from go-modbus/codec (e.g. float32/layout:4321, ascii/registers:4, ip_addr, datetime2_s2000)
value Typed JSON matching the codec (numbers, strings, byte arrays, RFC3339 times, IP/MAC strings)
span Derived from the codec register count — do not specify count; overlapping spans in one area are rejected

Discover IDs with modbus-simulator codecs list. Validation runs JSON Schema plus semantic encode/decode round-trip checks. Optional trace overlay: run --trace-decoded adds a decoded[] field when a read/write fully covers a codec field.

Supported function codes (v1)

FC Area
1, 5, 15 Coils
2 Discrete inputs (read-only)
3, 6, 16, 22, 23 Holding registers
4 Input registers (read-only)
43 / 14 Device identification
  • FC22 (mask write) sets the register to (current AND andMask) OR (orMask AND NOT andMask).
  • FC23 (read/write multiple) makes the write first, then the read, as one step. If either is not allowed, nothing is written.

All devices in a fixture share one listener and are routed by unit ID (1–247). A request for a unit ID that is not in the fixture is answered with an illegal_function exception.

State, reset and reload

A device's stateMode (set in defaults or per device in behavior) decides who sees a write:

stateMode State
persistent (default) One state shared by all clients, for as long as the simulator runs.
resetOnConnection Every client connection works on its own copy of the fixture values, discarded when it disconnects. Clients do not see each other's writes, and a new connection never disturbs one that is in progress.

With run --control <host:port> a running simulator also takes commands over HTTP, so a test suite can start it once and reset it between cases:

Request Effect
POST /reset Restore every unit to the fixture values, for all clients
POST /reset?unit=N Restore one unit (404 when it is not in the fixture)
POST /reload Read the fixture file again and serve it from then on. A fixture that is not valid is refused with 422 and the simulator carries on unchanged
GET /healthz 200 while the simulator runs
modbus-simulator run --fixture device.json --control 127.0.0.1:5021 &
curl -X POST http://127.0.0.1:5021/reset
curl -X POST http://127.0.0.1:5021/reload

Replies are JSON ({"ok":true}, or {"ok":false,"error":"…"}). The control API has no authentication: bind it to a loopback address. Resets and reloads are not written to the trace; seq simply continues.

Fault injection

Fault rules in a device's behavior.faults change how a matching request is answered (see REQUIREMENTS.md for the match grammar):

fault On the wire In the trace
delay The normal response, after delayMs ok: true, matchedRule
timeout No response; the connection stays open, so the client runs into its own timeout. delayMs, when set, is waited first ok: false, fault: "timeout"
connectionClose The connection is closed without a response ok: false, fault: "connectionClose"
{ "id": "hr-100-timeout", "match": { "fc": 3, "address": 100 }, "fault": "timeout" }

Broadcast

Set "broadcast": true at the top level of a fixture to make unit 0 the broadcast address, as on a serial line behind a gateway:

  • A write to unit 0 (FC 5, 6, 15, 16, 22) is executed by every device that can take it; a device where the address is unknown or read-only ignores it. No response is sent.
  • Any other request to unit 0 is ignored and left unanswered.
  • The trace has one record with "unitId": 0 and "response": {"ok": true, "noResponse": true}; each entry of stateChanges names the unitId it changed.
  • Exception and fault rules belong to a device and are not applied to a broadcast.

Without it (the default), unit 0 is an unknown unit and is answered with illegal_function.

TLS

Give run a server certificate, its key and a client CA to serve Modbus/TCP Security instead of plain TCP:

modbus-simulator run --fixture device.json --listen :8020 \
  --tls-cert server.pem --tls-key server.key --tls-client-ca ca.pem

All three are required: clients must present a certificate that chains to --tls-client-ca (mutual TLS). The trace records "transport": "tcp+tls".

Limitations

  • No RTU/serial server. The listener is TCP, plain or with TLS.
  • Codec fields are register areas only (no coil/bit codecs). Writes need not align with codec field boundaries; decoded[] (--trace-decoded) lists only fields fully covered by the request.
  • --trace-raw PDUs are re-encoded, not captured: the request as the simulator decoded it and the response it returned, encoded as the specification prescribes. Padding bits of an FC15 request are zero, and the response of FC43 is not included.

See RELEASE.md for per-release notes.

Examples

Ready-to-run fixtures in examples/ — 21 total (12 function-code, 9 codec bundles). Each file has a TCP integration test in TestExamplesIntegration (make test). Codec bundles are checked against modbus-simulator codecs list by TestExamples_AllCodecsHaveExample (195 IDs).

Function codes

Fixture FC Try it
fc01-read-coils.json 1 — Read coils modbus-simulator run --fixture examples/fc01-read-coils.json
fc02-read-discrete-inputs.json 2 — Read discrete inputs modbus-simulator run --fixture examples/fc02-read-discrete-inputs.json
fc03-read-holding-registers.json 3 — Read holding registers modbus-simulator run --fixture examples/fc03-read-holding-registers.json
fc04-read-input-registers.json 4 — Read input registers modbus-simulator run --fixture examples/fc04-read-input-registers.json
fc05-write-single-coil.json 5 — Write single coil modbus-simulator run --fixture examples/fc05-write-single-coil.json
fc06-write-single-register.json 6 — Write single register modbus-simulator run --fixture examples/fc06-write-single-register.json
fc15-write-multiple-coils.json 15 — Write multiple coils modbus-simulator run --fixture examples/fc15-write-multiple-coils.json
fc16-write-multiple-registers.json 16 — Write multiple registers modbus-simulator run --fixture examples/fc16-write-multiple-registers.json
fc22-mask-write-register.json 22 — Mask write register modbus-simulator run --fixture examples/fc22-mask-write-register.json
fc23-read-write-multiple-registers.json 23 — Read/write multiple registers modbus-simulator run --fixture examples/fc23-read-write-multiple-registers.json
fc43-device-identification.json 43/14 — Device identification modbus-simulator run --fixture examples/fc43-device-identification.json
all-function-codes.json 1–6, 15, 16 and 43 in one fixture modbus-simulator run --fixture examples/all-function-codes.json

Codecs — nine bundled fixtures cover every codec from modbus-simulator codecs list (195 IDs). Each file lists one example per family member with non-overlapping addresses.

Fixture Family Codecs Try it
codec-integers.json integer 29 modbus-simulator validate examples/codec-integers.json
codec-floats.json float 8 modbus-simulator validate examples/codec-floats.json
codec-text.json text 60 modbus-simulator validate examples/codec-text.json
codec-bcd.json bcd 48 modbus-simulator validate examples/codec-bcd.json
codec-bytes.json bytes 26 modbus-simulator validate examples/codec-bytes.json
codec-decimal-limb.json decimal_limb 12 modbus-simulator validate examples/codec-decimal-limb.json
codec-datetime.json time 8 modbus-simulator validate examples/codec-datetime.json
codec-network.json network 2 modbus-simulator validate examples/codec-network.json
codec-hardware.json hardware_address 2 modbus-simulator validate examples/codec-hardware.json

Regenerate bundled examples after adding codecs: make generate-codec-examples

Each fixture uses unit ID 1 on the default listen address :5020. The description field in every file summarizes the registers or coils to exercise.

Development

make help                      # list targets
make test                      # unit + race tests (includes example fixtures)
make check                     # fmt, lint, vet, test, coverage
make soak                      # loop the chaos and stress tests (SOAKTIME=2m)
make fuzz                      # run the fuzz targets (FUZZTIME=30s each)
make build                     # build bin/modbus-simulator
make build-all                 # cross-compile release binaries
make generate-codec-examples   # regenerate bundled codec fixtures

Shell completion setup is documented under completion.

Chaos, stress and fuzz tests

make test includes a short run of all of them:

  • Stress (stress_test.go) — parallel clients check every answer against a model of their own registers while they all contend for a shared block; connection churn, the client limit and shutdown with requests in flight.
  • Chaos (chaos_test.go) — misbehaving raw TCP clients (garbage, truncated and oversized frames, random PDUs, illegal quantities, slow loris, pipelining, half-closed and abandoned connections) run next to the well-behaved ones, which must not notice.
  • Fuzz (fuzz_test.go) — fixtures, expectation files and arbitrary request sequences.

After each run the trace must be schema-valid, numbered 1, 2, 3, … in file order, and replay as a sequential history: every read returns what the earlier writes left behind. Randomized tests log their seed; replay one with MODBUS_SIMULATOR_TEST_SEED=<seed>.