Research prototype. Not a validated medical device and not a substitute for clinical judgment.
An offline-first PWA that helps nurses at primary care facilities and in remote areas:
- compute qSOFA (Sepsis-3) deterministically from vital signs;
- measure Capillary Refill Time (CRT) with a phone camera (~22 s: rest 2 · press 10 · release 10), with a signal curve, quality checks, and an honest rejection when the data is poor;
- compose a referral draft from a template (offline) — copy, SMS, share sheet, or download as .txt.
CAPIRA does not diagnose sepsis or shock. CRT is shown as a supporting finding, separate from the qSOFA score.
| Engine accuracy (synthetic signals) | Measured — MAE 0.20–0.27 s, Bland-Altman ±0.5–0.8 s on results that pass the gate (VALIDATION.md) |
| Accuracy on real cameras / patients | Not yet measured (Phase 1: PROTOCOL.md) |
| Dark skin | Higher rejection rate on synthetic data; must be measured and reported per subject |
| Medical / statistical claims | Every claim has a status in CLAIMS.md |
npm install
npm test # 105 unit tests (engine, qSOFA, referral, storage, simulation, CSV)
npm run dev # http://localhost:5173
npm run build && npm run preview # production build + service workerThe interface is a responsive dashboard with desktop/mobile navigation, a dark mode that follows the system setting, a history view with search/filter, and handling for camera and storage failures. The home summary is derived from local data, including simulation records, which are labelled as such.
See the app review and follow-up work for the changes made, test coverage, and remaining limitations.
npx playwright install chromium # once, for browser tests
npm run test:ui # run after npm run dev
npm run build
npm run test:ui -- --production # automatic preview + offline testBrowser tests use an isolated profile. Reports and screenshots are written to artifacts/. For a dev server on another port, use CAPIRA_TEST_URL=http://localhost:PORT npm run test:ui.
The camera requires a secure context (HTTPS or localhost). To develop on an Android phone (Chrome), pick one:
adb reverse tcp:5173 tcp:5173, then openhttp://localhost:5173on the phone; or- an HTTPS tunnel (e.g.
cloudflared tunnel --url http://localhost:5173).
npm run build→ upload thedist/folder to static HTTPS hosting (Netlify, Vercel, GitHub Pages, Cloudflare Pages). Paths are relative, so a subfolder works too.- Open the URL once while online in Chrome for Android and wait for the "Ready offline" label on the home screen (the service worker has finished precaching every asset — no CDN).
- (Optional) Menu ⋮ → Add to Home screen.
- Turn on Airplane Mode and open the app again. The home screen, history, simulation, and result storage have been tested in headless Chromium with the network disabled; the camera flow still needs to be tested on the target phone.
5-minute demo script: docs/DEMO.md.
| Command | Purpose |
|---|---|
npm run accuracy -- --seeds=10 [--noiseModel=relative] |
Engine accuracy sweep on synthetic signals |
npm run analyze -- data/raw/*.csv |
Compare protocols A/B/C × 5 candidate signals from Experiment-page CSVs |
npm run compare -- annotations.csv data/raw/*.csv |
Engine CRT vs. blinded frame-by-frame annotation (≥2 annotators) |
In the app: Experiment (record + CSV export + camera capabilities), Annotate (mark release/recovery frames without seeing the engine result).
src/engine/ Vascular Refill Engine (pure, no DOM) + synthetic generator + CSV
src/clinical/ qSOFA, age-specific CRT interpretation, non-directive recommendation
src/referral/ template referral draft + MOCK facilities
src/storage/ IndexedDB (Dexie) — derived signal + metadata, no video
src/capture/ camera (torch/AE/AWB where supported), live frame sampler (rVFC), protocol cues
src/ui/ React UI (English)
Decisions and rationale: DECISIONS.md. What was deliberately cut: CUTLIST.md.
- Not validated on patients; healthy subjects do not prove detection of critical conditions.
- Quality thresholds are provisional (calibrated on synthetic signals).
- CRT is affected by temperature, age, hand position, and the force and duration of pressure; pressure force is not controlled.
- Exposure / white-balance lock is not available on every phone/browser; compensated by a reference patch plus a drift gate.
- The ROI is chosen manually (no automatic nail segmentation).
- Primary target is Chrome for Android; iOS Safari is best-effort (torch is reportedly supported since iOS 17.5 per WebKit, untested).
- Referral facility data is MOCK.
All processing happens on the device; the core flow makes no network requests. Stored locally: derived color signals, one small fingertip thumbnail, and form inputs. Video is not stored. Per-frame ROI crops are stored only if enabled in Experiment (with the subject's consent). Delete individual items or all data from History/About. Consult Indonesian Law No. 27/2022 (Personal Data Protection) before using with real patient data.