Celsiwire

Temperature logger for Windows that reads 1-Wire DS18B20 sensors through DS9097E or DS9097U serial adapters. It shows live values, records them to CSV files, and raises alarms when a sensor leaves its limits.

Source code: https://github.com/usbtemp/celsiwire

Sponsored by usbtemp.com

Features

  • Several sensors on several COM ports. The adapter type is detected automatically.
  • Measurement interval from 1 second to 10 minutes (default 5 seconds), plus custom values.
  • CSV files with one column per sensor. A new file is started after a set number of records or every day.
  • Status tab showing each sensor's value with its min, average and max since logging started.
  • Chart tab with the temperatures of the last day, week or month, one colour per sensor.
  • Low and high alarm limits per sensor, with hysteresis, an optional sound and a tray notification.
  • Alarm when a sensor has not been read for 1 minute during logging.
  • A USB adapter that is unplugged during logging is picked up again when it comes back, even on a different COM port. The same applies to an adapter that is missing when logging starts: its sensors keep their columns in the file and are read as soon as it is plugged in.
  • The serial port list refreshes by itself when a USB adapter is plugged in or removed (when not logging).
  • Calibration offset per sensor (±5 °C), applied to displayed, logged and alarm values.
  • Sensor names, so files and the status tab show names instead of ROM codes.
  • Tray icon: blue when idle, green while logging, red during an alarm. Its tooltip lists current values.
  • Logging indicator at the right end of the tab strip: a blinking green dot (red during an alarm) with the start time and the number of measurements. Its tooltip shows the interval and the current CSV file.
  • Taskbar badge: a green dot on the taskbar icon while logging, a red dot during an alarm (Windows 7 and newer).
  • Configurations can be saved to and loaded from XML files. While one is in use, the window title shows * when it has unsaved changes.
  • Start with Windows: Celsiwire can start minimized and begin logging automatically.
  • Only one instance runs per user: starting it again brings the running window to the front.
  • Copy to the clipboard (tab-separated, pastes into Excel columns): Log rows, Status values, a sensor's ROM or name, and the status bar message. Right-click to copy.

Screenshots

Status tab with live values, min, average and max per sensor

Chart tab with the temperatures of the last day

Requirements

  • Windows Vista or newer, including Windows Server 2008 R2. The taskbar badge needs Windows 7 or newer.
  • .NET Framework 4.0 or newer for Celsiwire.exe, or .NET Framework 3.5 for Celsiwire35.exe.
  • A DS9097E (passive) or DS9097U (DS2480B based) 1-Wire adapter on a serial or USB-serial port.

Usage

Quick start

  1. Connect the 1-Wire adapter with the sensors and start Celsiwire. It opens on the Devices tab.
  2. Select the serial port. In the Serial ports box, tick the COM port of the adapter. If it is not listed, press Refresh. The list also refreshes by itself when a USB adapter is plugged in.
  3. Detect the sensors. In the Sensors box, press Detect. Celsiwire finds the adapter type (DS9097E or DS9097U) and lists the sensors on the ticked ports by their ROM codes. Read shows their current temperatures.
  4. Select the sensors. Tick the sensors to log. To give a sensor a name, select it and press F2, or right-click it and choose Rename.
  5. Start logging. Press Start (F5) at the bottom right. Celsiwire switches to the Status tab with the live values, the Log tab lists every measurement, and the CSV files go to the folder set on the Settings tab. While logging, a blinking green dot next to the tabs and a green dot on the taskbar icon show that it is running. Press Stop (F8) to end logging.
  6. Watch the chart. The Chart tab draws the temperatures. The buttons Day, Week and Month in its top right corner choose how much it shows. The current time is the green dashed line in the middle, with the date above it and the time below it; the newest data is on its left and slides left as time passes. The right half shows the older data from before that, fading with age. Point at the chart to see the time and each sensor's value there. Alarm limits are drawn as dashed lines in the sensor's colour; Show alarm limits on the chart on the Settings tab turns them off. Right-click the chart to Save as PNG... or Copy image. The chart keeps only what was measured since Celsiwire was started.

Optional, before starting:

  • Sensors tab: a calibration offset and low and high alarm limits per sensor.
  • Settings tab: the measurement interval, the folder, the file name pattern and when to start a new file, and whether measurements are saved to local AppData when the folder cannot be written (on by default, after 1000 waiting lines).
  • Save configuration (Ctrl+S) keeps the ports, sensors and settings in a file that you can load later or start with Windows.

Allowed values

Setting Range Notes
Measure every (interval) 1 s to 1 day (86400 s) Pick from the list, or type seconds, minutes or hours (90, 90 s, 5 min, 2 hours) and press Enter
Records per file 1 or more, whole number Not used when New file every day is on
Offset -5.00 to +5.00 °C Empty means no offset
Low / High alarm limit -100 to 200 °C Empty means no limit; Low must be below High
Hysteresis 0.0 to 10.0 °C An alarm clears only when the value is this far back inside the limit
Waiting lines before saving to AppData 10 to 1,000,000 (default 1000) Lines waiting in memory while the log folder cannot be written
Sensor name Up to 40 characters, not starting with = Longer names are cut; empty shows the ROM code
No-reading alarm 1 minute Raised when a sensor has no good reading for this long during logging

Invalid values are shown with a light red background, and logging cannot start while the interval or records per file is invalid.

Keyboard shortcuts

Key Action
F5 Start logging
F6 Start logging and minimize to tray
F8 Stop logging
Ctrl+M Minimize to tray
Ctrl+L Load configuration
Ctrl+S Save configuration
Ctrl+1 … Ctrl+7 Switch tabs
F2 Rename sensor (Devices list; right-click for more)
Ctrl+C, Ctrl+A Copy, select all (Log tab)
Ctrl + close (X) Close without asking: stops logging, skips the save prompt

Command line

Celsiwire.exe [/config=<file>] [/autostart]
Option Meaning
/config=<file> Load this configuration at startup. /config:<file> and /config <file> also work.
/autostart Start logging and minimize to tray once the ports are ready. If no adapter is plugged in yet, logging starts anyway and waits for it.

Options are case-insensitive and can start with / or -. The Start with Windows checkbox registers "<program folder>\Celsiwire.exe" /autostart /config="<current configuration>" under HKCU\Software\Microsoft\Windows\CurrentVersion\Run. /config is left out when no configuration file is in use.

Files

File Contents
%AppData%\Celsiwire\settings.xml Logging and alarm settings, sensor names, offsets and limits. Written automatically when the app closes, unless a configuration file was loaded or saved in that session.
%AppData%\Celsiwire\celsiwire.log Application log (start, stop, errors, alarms). Rotated at 1 MB.
*.xml (your choice) Saved configuration: settings plus the selected ports and sensors. Written only by Save configuration.
*.csv Measurements
%LocalAppData%\Celsiwire\*.csv Measurements that could not be written to the log folder: when more than 1000 lines are waiting (the number is set on the Settings tab), or when logging stops while the folder is still unavailable. Same file name, with the header. Turned off with Save waiting lines to local AppData on the Settings tab.

CSV format

  • The first column holds the time (yyyy-MM-dd HH:mm:ss). Each further column holds one sensor, with a header like Office (28014B467FFF0CCB).
  • The separator and the decimal sign follow the Windows regional settings, so the files open directly in Excel.
  • The default folder is the program folder if it is writable, otherwise Documents\Celsiwire.
  • The default file name pattern is Celsiwire_%Y%m%d_%H%M%S.csv. Patterns use strftime-style tokens (%Y, %m, %d, %H, %M, %S, %F, %T, %n for the file number, …); the tooltip next to the field lists them all.

Building

The project is SDK-style and targets net40 and net35. It uses C# 7.0, so it also builds in Visual Studio 2017.

dotnet build Celsiwire.sln -c Release
Output Target
Celsiwire/bin/Release/net40/Celsiwire.exe .NET Framework 4.0
Celsiwire/bin/Release/net35/Celsiwire35.exe .NET Framework 3.5

The .NET SDK builds both targets on any OS, Linux included: the reference assemblies come from NuGet. The .NET analyzers run at the Recommended level, and .editorconfig holds the project's rule settings.

Repository layout

Each file in Celsiwire/ is named after its namespace and class, e.g. ControllerLogging.cs holds Controller.Logging. A class split over several files adds the part's name: DisplayMainFormTray.cs is the tray part of Display.MainForm.

Path Contents
Celsiwire/Program*.cs Entry point, command-line options, single instance
Celsiwire/Display*.cs Windows Forms user interface: main window, tabs, tray, taskbar badge
Celsiwire/DisplayControls*.cs Own controls: chart, toggle button, logging indicator and others
Celsiwire/Controller*.cs Port and adapter detection, sensor reading, logging, CSV files, alarms, chart history
Celsiwire/Configuration*.cs Settings, ports and sensors; XML load and save
Celsiwire/Data*.cs Plain data: a measurement, a sensor's min/avg/max, a chart point, a USB adapter's VID/PID and name
Celsiwire/Utils*.cs Paths, application log, start with Windows, file name patterns, USB port names, window messages
Celsiwire/Consts.cs Program name, links, colours, layout sizes and default values
Celsiwire/owcs/ 1-Wire library: DS9097E and DS9097U adapters, DS18B20 sensor, CRC
Celsiwire/icons/ Application icon and the green and red tray icons
.github/workflows/build.yml Pushing a v* tag builds both exes and creates a GitHub release with them and SHA256SUMS

License

MIT, see LICENSE.md.